From every station to one namespace.

Each machine on your line keeps talking the protocol it already speaks. A plant box on your floor reads them all, read-only, and publishes one structured view of the line: the Unified Namespace.

READ-ONLYSTANDARD PROTOCOLSONE LINE FIRST
[How it works]

Eight stations, one plant box.

Stations are shown in the order a pack is built. Each dashed line is a read-only connection over the protocol that station already uses.
1
Incoming cell check
Barcode scanner and MES
Cell lot, supplier, count
MES + scan
2
Cell sorting, grading
Sorting machine PLC
Voltage, resistance, grade
OPC UA
3
Module stacking
Stacking station PLC
Cell to module mapping
Siemens S7
4
Laser welding
Laser welder controller
Weld power, time, result
Modbus TCP
5
BMS fit and flash
Flashing PC
BMS serial, firmware
File export
6
Pack assembly, sealing
Torque tools, leak tester
Torque, leak test result
EtherNet/IP
7
End-of-line test
EOL tester PC
Capacity, pass or fail
Database / CSV
8
Rework and dispatch
ERP, MES or operator tablet
Rework reason, final status
ERP / MES / manual
Plant box (edge gateway on your floor)
Reads every station, read-only. Buffers data if the internet drops.
Ospra UNS and FloorSight
One namespace for the line. Dashboards, traceability and the baseline report.

Protocols shown are typical examples. The protocol, PLC model and capture method for each station are confirmed during discovery. MQTT and Sparkplug B are also supported. Stations with no PLC or no network interface use file pickup, export or manual entry.

[The namespace]

One address for every reading.

Site, line, station, machine, data. Every station publishes in the same shape, so a pack can be followed from cell lot to end-of-line result.
Site > Line > Station > Machine > Data
  • your-plantSite
    • pack-line-1Line
      • cell-sortingStation
        • sorter-01Machine
          • voltageData
          • resistance
          • grade
      • laser-welding
        • welder-02
          • weld-power
          • weld-result
      • eol-test
        • tester-01
          • capacity
          • result
One reading, as it lands (example)
your-plant/pack-line-1/cell-sorting/sorter-01/voltage
{
  "value": 3.287,
  "unit": "V",
  "cell_lot": "CL-2411-07",
  "pack_serial": "PK-000482",
  "time": "2026-11-16T09:42:11Z"
}
[What you get]

What the line gives back.

01

One view of the line

Every station's data in one place, under one naming scheme, instead of separate machine screens, files and registers.

EVERY STATION > ONE VIEW
02

Floor traceability for end-of-line test issues

When a pack fails its end-of-line test, follow it back through every station to the weld, the module and the cell lot it came from.

EOL FAILURE > STATION > CELL LOT
03

Scrap and rework, quantified with cost

Scrap and rework counted by station, cause and cell lot, with a cost against each, including the rework that goes unrecorded today.

SCRAP AND REWORK > COST
04

Works with what you have, scales when you are ready

Standard protocols where there is a PLC, files or a manual entry screen where there is not. Read-only, with no change to control logic. The same namespace extends to the next line.

READ-ONLY > NEXT LINE READY
[Get Started]

Standardize the data across every siloed system.
See what your floor is already telling you.
Then optimize what's actually costing you.